anim
anim
anim
  • All Categories
  • E-Services
  • NahdiNahdi Global
  • FlashFlash Sales
  • PromoPromo Flyer
  • NahdicareNahdicare Health center
  • MilkMilk Promo Flyer
  • Home
  • Sleep Apnea & Oxygen Devices
  • Genuine  brands

    Genuine brands


  • Temperature Controlled

    Temperature Controlled


  • Secure Payment

    Secure Payment

About Product

Product Description:


SUMMARY 



  • The oxygen concentrator is intended for individual use at home. It is an electronically operated device that separates oxygen from room air. It provides high concentration of oxygen directly to you through a nasal cannula. Clinical studies have documented that oxygen concentrators are therapeutically equivalent to other types of oxygen delivery systems. 

  • This user's manual will tell you about your concentrator and will serve as a reference as you use your concentrator. 


CHARACTERS 



  • Complete plastic out shell, safe and reliable. Timing accumulates function, show total operating hours through the display screen. 



  • Timing turns off function using convenience. 



  • Compressor pressure relief valve help the device safer. 



  • Power interruption alarm function. 



  • Device failure alarm function (including pressure/cycle failure, compressor failure, low oxygen concentration). 



  • Compressor with over heat protect function to gain in safety of the compressor and the concentrator. 



  • Nebulizing function



  • Remote control function. 


SPECIFICATIONS 


1. Maximum Recommend Flow Rate: 5L/min


2. Flow Range: 0~5L/min 


3. Change in maximum recommended flow when back pressure of 7kPa is applied: 0.5L/min


4. Oxygen Concentration: 95.5% ~ 87% 


5. Output Pressure: 40 ~ 70kPa 


6. Pressure Relief Mechanism Operational at: 250kPa+25kPa (36.25psit3.63psi) 


7. Sound Level: (8F5A, 8FSAW) Average (Front Side): 48dB(A), whole unit: 52dB(A). 


8. Maximum Nebulizing Rate:



  • 0.15mL/min


9. Power Supply: DACI20V+10% FAC220V410% FAC230V+10% 


OS50Hz+2% 560Hz+2% 


10. Input Power: 400VA 


11. Net Weight: 15.5kg


12. Dimension: W39cm(15.4") x D24.5cm(9.7 ") x H50cm(19.7 *) 


13. Altitude: Up to 1828 meters (6000 ft) above sea level without degradation of concentration levels. From 1828 meters (6000 ft) to 4000 meters (13129 ft) below 90% efficiency. 


14. Safety System: 


Over Current or Connection Loosen: Unit Shut Down 


Compressor Over Hot: Unit Shut Down 


Pressure, Cycle Failure: Alarming and Shut Down 


Compressor Failure: Alarming and Shut Down 


Low Oxygen Concentration 


16. Minimum Operating Time: 30minutes 


17. Electric classification: class II equipment, type BF applied part 


18. Work system: work continuously. 


19. Normal Operating Condition: 


Temperature range: 10°C ~ 40°C (50 F ~ 104F) 


Relative humidity: 30% ~ 75% 


Atmosphere pressure: 860hPa ~ 1060hPa (12.47psi ~ 15.37psi) 


CAUTION: When storage/transportation condition is lower than 5°C , please put the device in normal operating condition more than 4 hours before operating. 


20. Oxygen Output Temperature: < 46°C 


21. Cannula length DO NOT more than 15.2m (50ft) and no twist. 


22. Storage and Transportation Condition: 


Temperature range: 20°C ~ 60°C (4F ~ 140F) 


Relative humidity: 10% ~ 93% Noncondensing. 


Atmosphere pressure: 700hPa ~ 1060hPa (10.15psi ~ 15.37psi) 


CAUTION: The device should be stored with no strong sunlight, no corrosive gas and well ventilated indoor area. The device must be transported and used in the vertical position only.


How to use:


PREPARE WORK 


1.Unscrew the bottle from the humidifier clockwise. Fill the bottle with pure water (or distilled water) to the level between MAXIMUM and MINIMUM. DO NOT fill humidifier bottle over MAXIMUM level. (Figure 5) 


2. Screw securely the bottle back counterclockwise. (Recommend to use Yuwell Humidifier p/n: 2.05.014.114) 


3. Connect the power supply.


CAUTION:


1) If the concentrator has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into liquid, call Qualified Service Personnel for examination and repair. 


2) Keep the cord away from HEATED or HOT surfaces. 


3) Do not move or relocate concentrator by pulling on the cord. 


4) Do not use extension cords with this unit. 


NOTE: Concentrator may be used during the initial start warmup time (approximately 30 min) while waiting for the O2 purity to reach maximum. 


II. OXYGEN ABSORBING OPERATION 


1. FLOWRATE (Figure 6 ) 



  • Turn the flowrate knob to the setting prescribed by your physician or therapist. 


NOTE: To properly read the flowrate, locate the prescribed flowrate line on the flowmeter. 



  • Next, turn the flow knob until the ball rises to the line. Now, center the ball on the L/min line prescribed.


CAUTION: If the flowrate on the flowmeter ever falls below 0.5L/min, check tubing or accessories for blocked or kinked tubing or a defective humidifier bottle. 



  • Meanwhile, humidifier bottle will have air bubble around the sieve core. Then, oxygen comes from the oxygen outlet. 


2. Connect nasal oxygen cannula to oxygen outlet, the other end match the patient. 


Note: The time of absorbing oxygen and the flowrate range according to the 


doctor's advices. 


NEBULIZING OPERATION



  • Fill proper medicinal liquid in the nebulizing cup (Please follow the doctor's advices or don't exceed the maximum reticle of the nebulizing cup). 

  • Upward pull out the nebulizing cover on the nebulizing interface. 


Counter clockwise


Nebulizing Cap 


Nebulizing Interface 



  • Connect the air hose to nebulizing cup and nebulizing interface, then turn on the power of the oxygen concentrator, now can begin nebulizing therapy immediately. 

  • When drug nebulizing have finished, turn the nebulizing cover right to nebulizing interface for tightening. If you won't breathe oxygen, please turn off the oxygen concentration. 

  • Pull out the air hose, pull the mouthpiece, downward pull the nebulizing cup's cap, empty remained medicinal liquid in the nebulizing cup, then wash 

  • the air hose, mouthpiece, nebulizing cup's cap, nebulizing baffle, nebulizing cup, ripple tube, Tpiece, etc. , with pure water or immerge them in warm water for about 15 minutes. In order to wash them healthy, you may add some vinegar in water. (NOTE: DO NOT cook the accessories above for wash or wash them with boiled water, in case they'll distort when heating). 

  • After finishing cleaning, must dry all the components before storage. 


NOTE: The timing for using nebulizer must follow the doctor's advices.


ALARM SIGNAL 


Concentrator has following failure alarm function: 


1) Pressure and cycle failure 


2) Compressor failure 


3) Low oxygen concentration 


Note : All the alarms of the device are low priority.


Caution & Warnings:


WARNING: INDICATION FOR USE 



  • For avoiding power outage or oxygen concentrator operating failure, exigent oxygen user and serious patient must equip with reserve oxygen supply (for example: oxygen cylinder, oxygen bag). This device is to be used as an oxygen supplement. It is not intended for life supporting, or life sustaining applications nor does it provide any patient monitoring capabilities. 


WARNING: CONTRAINDICATIONS 



  • The oxygen concentrator is not intended for life supporting or life sustaining applications, nor does it provide any patient monitoring capabilities. 


Symbol Description 


WARNING Describes a hazard or unsafe practice that if not avoided can result in severe bodily injury, death or property damage. 


CAUTION Describes a hazard or unsafe practice that if not avoided can result in minor bodily injury or property damage. 


I . IMPORTANT MESSAGE 



  • To reduce the risk of electrical shock, DO NOT remove the cabinet. Refer service to qualified service personnel.

  • Before operating the device, read and understand this manual. 


II. BEFORE INSTALLATION 



  • The concentrator should always be kept upright to prevent cabinet damage while being transported. 

  • If the electrical source power voltage is unstable that beyond normal power rang, please add the voltage stabilizer. 

  • Please use eligible, safe power set and junction box. 

  • Nonprofessional people DO NOT open oxygen concentrators cabinet.


II. LOCATING 



  • You may select a room in your house where using your oxygen concentrator 

  • would be most convenient. Your concentrator can easily move from one 

  • room to other room by the wheels. 

  • Be certain to place the device so all sides are at least 10 cm (4 inches) away 

  • from walls, draperies, furniture, or other obstruction. DO NOT place the 

  • unit in a confined area. 

  • Oxygen concentrator must avoid heat source, fire source, wetness, 

  • exorbitant or overlow extra ventricular condition. 

  • Sundries and vessel do not be placed on top of the concentrator. 


SAFETY NOTES 



  • NEVER block the air openings of the unit or place it on a soft surface, such 

  • as a bed or couch, where the air opening may be blocked. Keep the openings 

  • free from lint, hair and the like. 


IV. USING 


The use of oxygen therapy requires that special care be taken to reduce the 


risk of fire. Users MUST NOT SMOKE while using this device. Keep all 


matches, lighted cigarettes or other sources of ignition out of the room in 


which this product is located. NO SMOKING signs should be prominently 


displayed. Textiles and other materials that normally would not burn are 


easily ignited and burn with great intensity in oxygen enriched air. Failure to 


observe this warning can result in severe fire, property damage and cause 


physical injury or death. 


For optimum performance, do not open or turn off the concentrator 


frequently, reset after 3 ~ 5 minutes. Shorter periods of operation may reduce 


maximum product life. 


A spontaneous and violent ignition may occur if oil, grease or greasy 


substances come in contact with oxygen under pressure. These substances 


MUST be kept away from the oxygen concentrator, tubing and connections, 


and all other oxygen device. 


DO NOT use any lubricants unless recommended by manufacturer. 


V. MAINTENANCE 



  • The oxygen concentrator was specifically designed to minimize routine 


preventive maintenance at intervals of once per year. Only professionals of 


the healthcare field or persons fully conversant with this process such as 


authorized or factory trained personnel should perform preventive 


maintenance or performance adjustments on the oxygen concentrator. 


VI. RADIO FREQUENCY INTERFERENCE 


This equipment generates, uses and can radiate radio frequency energy and, 


if not installed according with the instructions, may cause harmful 


interference to other devices in the vicinity. However, there is no guarantee 


that interference will not occur in a particular installation. If this equipment 


does cause harmful interference to other devices, which can be determined 


by turning the equipment off and on, the user is encouraged to try to correct 


the interference by one or more of the following measures: 


Reorient or relocate the receiving device. 


Increase the separation distance between the equipment. 


Connect the equipment into an outlet on a circuit different from that which 


the other device(s) are connected. 


Consult the manufacturer or service technician for help. 


Vl. TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE OR INJURY TO PERSONS



  • Avoid using while bathing. If continuous usage is required by the physician's 


prescription: 


The concentrator must be located in another room at least 2.5m from the bath. 


DO NOT come in contact with the concentrator while wet. 


DO NOT place or store product where it can drop into water or other liquid. 


DO NOT reach for product that has fallen into water. UNPLUG 


IMMEDIATELY. 


A product should NEVER be left unattended when plugged in. 


This device is to be used only in accordance with the prescription of a 


physician and this User's Manual. If at any time the patient or attendant 


concludes that the patient is receiving an insufficient amount of oxygen, the 


supplier and/or physician should be contacted immediately. No adjustments 


should be made to the flowrate unless prescribed by a physician. 


Close supervision is necessary when this product is used near children or 


physicallychallenged individuals. 


Use this product for only intended use as described in this manual. 


DO NOT use parts, accessories or adapters other than those authorized by 


manufacturer. 


DO NOT connect the concentrator in parallel or series with other oxygen 


concentrators or oxygen therapy devices. 


Use of some administration accessories or certain humidifiers not specified 


for use with oxygen concentrator may impair the performance. 


In certain circumstances oxygen therapy can be hazardous. Manufacturer 


recommends that you seek medical advice before using this product. 


Avoid creation of any spark near medical oxygen equipment. This includes 


sparks from static electricity created by any type of friction. 


The shelf life of the device is 5 years after starting operating.


Components:



  • 8F5AW Oxygen Concentrator, Nasal oxygen cannula, User's manual, Filter, Nebulizer, Warranty card, Remote control



Product Details:

  • Brand: Yuwell

Sleep Apnea & Oxygen Devices
Yuwell

Yuwell Oxygen Concentrator 5 Liters Gen 8 (8F-5A)

3,500.00 SAR

  • Brand: Yuwell

Product Description:


SUMMARY 



  • The oxygen concentrator is intended for individual use at home. It is an electronically operated device that separates oxygen from room air. It provides high concentration of oxygen directly to you through a nasal cannula. Clinical studies have documented that oxygen concentrators are therapeutically equivalent to other types of oxygen delivery systems. 

  • This user's manual will tell you about your concentrator and will serve as a reference as you use your concentrator. 


CHARACTERS 



  • Complete plastic out shell, safe and reliable. Timing accumulates function, show total operating hours through the display screen. 



  • Timing turns off function using convenience. 



  • Compressor pressure relief valve help the device safer. 



  • Power interruption alarm function. 



  • Device failure alarm function (including pressure/cycle failure, compressor failure, low oxygen concentration). 



  • Compressor with over heat protect function to gain in safety of the compressor and the concentrator. 



  • Nebulizing function



  • Remote control function. 


SPECIFICATIONS 


1. Maximum Recommend Flow Rate: 5L/min


2. Flow Range: 0~5L/min 


3. Change in maximum recommended flow when back pressure of 7kPa is applied: 0.5L/min


4. Oxygen Concentration: 95.5% ~ 87% 


5. Output Pressure: 40 ~ 70kPa 


6. Pressure Relief Mechanism Operational at: 250kPa+25kPa (36.25psit3.63psi) 


7. Sound Level: (8F5A, 8FSAW) Average (Front Side): 48dB(A), whole unit: 52dB(A). 


8. Maximum Nebulizing Rate:



  • 0.15mL/min


9. Power Supply: DACI20V+10% FAC220V410% FAC230V+10% 


OS50Hz+2% 560Hz+2% 


10. Input Power: 400VA 


11. Net Weight: 15.5kg


12. Dimension: W39cm(15.4") x D24.5cm(9.7 ") x H50cm(19.7 *) 


13. Altitude: Up to 1828 meters (6000 ft) above sea level without degradation of concentration levels. From 1828 meters (6000 ft) to 4000 meters (13129 ft) below 90% efficiency. 


14. Safety System: 


Over Current or Connection Loosen: Unit Shut Down 


Compressor Over Hot: Unit Shut Down 


Pressure, Cycle Failure: Alarming and Shut Down 


Compressor Failure: Alarming and Shut Down 


Low Oxygen Concentration 


16. Minimum Operating Time: 30minutes 


17. Electric classification: class II equipment, type BF applied part 


18. Work system: work continuously. 


19. Normal Operating Condition: 


Temperature range: 10°C ~ 40°C (50 F ~ 104F) 


Relative humidity: 30% ~ 75% 


Atmosphere pressure: 860hPa ~ 1060hPa (12.47psi ~ 15.37psi) 


CAUTION: When storage/transportation condition is lower than 5°C , please put the device in normal operating condition more than 4 hours before operating. 


20. Oxygen Output Temperature: < 46°C 


21. Cannula length DO NOT more than 15.2m (50ft) and no twist. 


22. Storage and Transportation Condition: 


Temperature range: 20°C ~ 60°C (4F ~ 140F) 


Relative humidity: 10% ~ 93% Noncondensing. 


Atmosphere pressure: 700hPa ~ 1060hPa (10.15psi ~ 15.37psi) 


CAUTION: The device should be stored with no strong sunlight, no corrosive gas and well ventilated indoor area. The device must be transported and used in the vertical position only.


How to use:


PREPARE WORK 


1.Unscrew the bottle from the humidifier clockwise. Fill the bottle with pure water (or distilled water) to the level between MAXIMUM and MINIMUM. DO NOT fill humidifier bottle over MAXIMUM level. (Figure 5) 


2. Screw securely the bottle back counterclockwise. (Recommend to use Yuwell Humidifier p/n: 2.05.014.114) 


3. Connect the power supply.


CAUTION:


1) If the concentrator has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into liquid, call Qualified Service Personnel for examination and repair. 


2) Keep the cord away from HEATED or HOT surfaces. 


3) Do not move or relocate concentrator by pulling on the cord. 


4) Do not use extension cords with this unit. 


NOTE: Concentrator may be used during the initial start warmup time (approximately 30 min) while waiting for the O2 purity to reach maximum. 


II. OXYGEN ABSORBING OPERATION 


1. FLOWRATE (Figure 6 ) 



  • Turn the flowrate knob to the setting prescribed by your physician or therapist. 


NOTE: To properly read the flowrate, locate the prescribed flowrate line on the flowmeter. 



  • Next, turn the flow knob until the ball rises to the line. Now, center the ball on the L/min line prescribed.


CAUTION: If the flowrate on the flowmeter ever falls below 0.5L/min, check tubing or accessories for blocked or kinked tubing or a defective humidifier bottle. 



  • Meanwhile, humidifier bottle will have air bubble around the sieve core. Then, oxygen comes from the oxygen outlet. 


2. Connect nasal oxygen cannula to oxygen outlet, the other end match the patient. 


Note: The time of absorbing oxygen and the flowrate range according to the 


doctor's advices. 


NEBULIZING OPERATION



  • Fill proper medicinal liquid in the nebulizing cup (Please follow the doctor's advices or don't exceed the maximum reticle of the nebulizing cup). 

  • Upward pull out the nebulizing cover on the nebulizing interface. 


Counter clockwise


Nebulizing Cap 


Nebulizing Interface 



  • Connect the air hose to nebulizing cup and nebulizing interface, then turn on the power of the oxygen concentrator, now can begin nebulizing therapy immediately. 

  • When drug nebulizing have finished, turn the nebulizing cover right to nebulizing interface for tightening. If you won't breathe oxygen, please turn off the oxygen concentration. 

  • Pull out the air hose, pull the mouthpiece, downward pull the nebulizing cup's cap, empty remained medicinal liquid in the nebulizing cup, then wash 

  • the air hose, mouthpiece, nebulizing cup's cap, nebulizing baffle, nebulizing cup, ripple tube, Tpiece, etc. , with pure water or immerge them in warm water for about 15 minutes. In order to wash them healthy, you may add some vinegar in water. (NOTE: DO NOT cook the accessories above for wash or wash them with boiled water, in case they'll distort when heating). 

  • After finishing cleaning, must dry all the components before storage. 


NOTE: The timing for using nebulizer must follow the doctor's advices.


ALARM SIGNAL 


Concentrator has following failure alarm function: 


1) Pressure and cycle failure 


2) Compressor failure 


3) Low oxygen concentration 


Note : All the alarms of the device are low priority.


Caution & Warnings:


WARNING: INDICATION FOR USE 



  • For avoiding power outage or oxygen concentrator operating failure, exigent oxygen user and serious patient must equip with reserve oxygen supply (for example: oxygen cylinder, oxygen bag). This device is to be used as an oxygen supplement. It is not intended for life supporting, or life sustaining applications nor does it provide any patient monitoring capabilities. 


WARNING: CONTRAINDICATIONS 



  • The oxygen concentrator is not intended for life supporting or life sustaining applications, nor does it provide any patient monitoring capabilities. 


Symbol Description 


WARNING Describes a hazard or unsafe practice that if not avoided can result in severe bodily injury, death or property damage. 


CAUTION Describes a hazard or unsafe practice that if not avoided can result in minor bodily injury or property damage. 


I . IMPORTANT MESSAGE 



  • To reduce the risk of electrical shock, DO NOT remove the cabinet. Refer service to qualified service personnel.

  • Before operating the device, read and understand this manual. 


II. BEFORE INSTALLATION 



  • The concentrator should always be kept upright to prevent cabinet damage while being transported. 

  • If the electrical source power voltage is unstable that beyond normal power rang, please add the voltage stabilizer. 

  • Please use eligible, safe power set and junction box. 

  • Nonprofessional people DO NOT open oxygen concentrators cabinet.


II. LOCATING 



  • You may select a room in your house where using your oxygen concentrator 

  • would be most convenient. Your concentrator can easily move from one 

  • room to other room by the wheels. 

  • Be certain to place the device so all sides are at least 10 cm (4 inches) away 

  • from walls, draperies, furniture, or other obstruction. DO NOT place the 

  • unit in a confined area. 

  • Oxygen concentrator must avoid heat source, fire source, wetness, 

  • exorbitant or overlow extra ventricular condition. 

  • Sundries and vessel do not be placed on top of the concentrator. 


SAFETY NOTES 



  • NEVER block the air openings of the unit or place it on a soft surface, such 

  • as a bed or couch, where the air opening may be blocked. Keep the openings 

  • free from lint, hair and the like. 


IV. USING 


The use of oxygen therapy requires that special care be taken to reduce the 


risk of fire. Users MUST NOT SMOKE while using this device. Keep all 


matches, lighted cigarettes or other sources of ignition out of the room in 


which this product is located. NO SMOKING signs should be prominently 


displayed. Textiles and other materials that normally would not burn are 


easily ignited and burn with great intensity in oxygen enriched air. Failure to 


observe this warning can result in severe fire, property damage and cause 


physical injury or death. 


For optimum performance, do not open or turn off the concentrator 


frequently, reset after 3 ~ 5 minutes. Shorter periods of operation may reduce 


maximum product life. 


A spontaneous and violent ignition may occur if oil, grease or greasy 


substances come in contact with oxygen under pressure. These substances 


MUST be kept away from the oxygen concentrator, tubing and connections, 


and all other oxygen device. 


DO NOT use any lubricants unless recommended by manufacturer. 


V. MAINTENANCE 



  • The oxygen concentrator was specifically designed to minimize routine 


preventive maintenance at intervals of once per year. Only professionals of 


the healthcare field or persons fully conversant with this process such as 


authorized or factory trained personnel should perform preventive 


maintenance or performance adjustments on the oxygen concentrator. 


VI. RADIO FREQUENCY INTERFERENCE 


This equipment generates, uses and can radiate radio frequency energy and, 


if not installed according with the instructions, may cause harmful 


interference to other devices in the vicinity. However, there is no guarantee 


that interference will not occur in a particular installation. If this equipment 


does cause harmful interference to other devices, which can be determined 


by turning the equipment off and on, the user is encouraged to try to correct 


the interference by one or more of the following measures: 


Reorient or relocate the receiving device. 


Increase the separation distance between the equipment. 


Connect the equipment into an outlet on a circuit different from that which 


the other device(s) are connected. 


Consult the manufacturer or service technician for help. 


Vl. TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE OR INJURY TO PERSONS



  • Avoid using while bathing. If continuous usage is required by the physician's 


prescription: 


The concentrator must be located in another room at least 2.5m from the bath. 


DO NOT come in contact with the concentrator while wet. 


DO NOT place or store product where it can drop into water or other liquid. 


DO NOT reach for product that has fallen into water. UNPLUG 


IMMEDIATELY. 


A product should NEVER be left unattended when plugged in. 


This device is to be used only in accordance with the prescription of a 


physician and this User's Manual. If at any time the patient or attendant 


concludes that the patient is receiving an insufficient amount of oxygen, the 


supplier and/or physician should be contacted immediately. No adjustments 


should be made to the flowrate unless prescribed by a physician. 


Close supervision is necessary when this product is used near children or 


physicallychallenged individuals. 


Use this product for only intended use as described in this manual. 


DO NOT use parts, accessories or adapters other than those authorized by 


manufacturer. 


DO NOT connect the concentrator in parallel or series with other oxygen 


concentrators or oxygen therapy devices. 


Use of some administration accessories or certain humidifiers not specified 


for use with oxygen concentrator may impair the performance. 


In certain circumstances oxygen therapy can be hazardous. Manufacturer 


recommends that you seek medical advice before using this product. 


Avoid creation of any spark near medical oxygen equipment. This includes 


sparks from static electricity created by any type of friction. 


The shelf life of the device is 5 years after starting operating.


Components:



  • 8F5AW Oxygen Concentrator, Nasal oxygen cannula, User's manual, Filter, Nebulizer, Warranty card, Remote control



Product Details:

  • Brand: Yuwell
  • Genuine  brands

    Genuine brands


  • Temperature Controlled

    Temperature Controlled


  • Secure Payment

    Secure Payment

  • Brand: Yuwell